Source
arXiv - Instrumentation and Detectors (physics.ins-det)
Licence and terms
Licence: arXiv metadata, CC0 1.0. arXiv metadata is CC0 1.0. API terms: one connection, at most 1 request per 3 s (enforced by Nupdate's per-host delay). Metadata only; PDFs are not CC0.
Metadata from arXiv.org (CC0 1.0). Papers themselves are not CC0; follow the link for the full text.
Publisher terms (opens in new tab)
Recent items
arXiv:2611.24776v1 Announce Type: new Abstract: Electron ptychography recovers atomic structure from 4D-STEM data: diffraction patterns at multiple positions of a scanned probe. Current codes reconstruct an image and read atoms off it, or fit atoms under an $L_1$ loss; neither gives per-atom uncertainty. We propose 4D-TEMPO, a differentiable physical renderer that fits the atoms, the microscope, and the detector directly to the recorded electron counts under a Poisson likelihood. The output is a list of atoms, each a Gaussian primitive with a 3D position, a thermal width, and a…
arXiv:2611.22872v1 Announce Type: cross Abstract: Mechanical cryocoolers offer numerous benefits for the operation of vacuum systems containing trapped atomic ions. However, the fidelity of laser-based gates can be degraded by phase noise induced by the cryocooler vibrations. We present a feed-forward vibration-cancellation system that directly measures inner shield displacement with an auxiliary interferometer and applies a compensating phase correction to the laser drive. The interferometer signal is demodulated, and a field-programmable gate array (FPGA) system unwraps the displacement…
arXiv:2611.15666v2 Announce Type: replace Abstract: Energy-deposition fluctuations determine the isotope-separation capability of multilayer silicon detectors. We measure the central peak widths of $^{124}$Xe signals in 300- and 675-micrometre silicon layers at incident energies of approximately 152-274 MeV per nucleon and compare them with Geant4 11.4.0 electromagnetic option 4 (emopt4) and a calculation with explicit charge exchange. In the 300-micrometre detector, the emopt4 relative width of 1.844% exceeds the unselected experimental width of 1.407% by 31% and the selected width of 1.060…
arXiv:2509.16281v2 Announce Type: replace Abstract: The LZ experiment is a liquid xenon time-projection chamber (TPC) searching for evidence of particle dark matter interactions. In the simplest assumption of elastic scattering, many dark matter models predict an energy spectrum which rises quasi-exponentially with decreasing energy transfer to a target atom. LZ has recently reported evidence for coherent elastic neutrino-nucleus scattering (CE$\nu$NS) of $^{8}$B solar neutrinos, a signal nearly identical to that expected from a dark matter particle with a mass of about 5.5 GeV/$c^{2}$, which…
arXiv:2606.15014v2 Announce Type: replace-cross Abstract: We propose a novel measurement of $\beta$ decays using low-temperature solid-state detector technologies. The $\beta$ startpoint, where the $\beta$ kinetic energy is zero, offers a unique probe of weak nuclear physics that has not yet been exploited experimentally. We describe how this technique enables searches for heavy sterile neutrinos in the keV--MeV energy range and show that, with current technologies, sensitivities to sterile neutrino coupling to electrons can be achieved that exceed the current best constraints. The spectrum…
arXiv:2611.15759v2 Announce Type: replace Abstract: CCGeant4 models energy-loss fluctuations of heavy ions in Geant4, accounting for both charge exchange and relativistic corrections to electron scattering beyond the first Born approximation. We use GLOBAL cross sections for electron capture and loss, ATIMA equilibrium stopping powers and charge-dependent delta-electron spectra calculated from the Dirac equation in a frozen-shell potential. The package also supports tabulated elastic ion-nucleus scattering. The silicon example includes interference between Coulomb and nuclear scattering…
arXiv:2601.13766v2 Announce Type: replace Abstract: BULLKID-DM is an experiment designed for the direct searches of particle dark matter candidates with mass around 1 GeV, or below, and cross-section with nucleons smaller than $10^{-40}$ cm$^2$. The detector consists of a stack of diced silicon wafers, acting as arrays of particle absorbers, sensed by multiplexed Kinetic Inductance Detectors. The target will amount to 800 g subdivided in more than 2000 silicon dice, with the aim of controlling the background from natural radioactivity by creating a fully active structure and by applying…
arXiv:2611.17364v1 Announce Type: new Abstract: This study investigates neutron flux redistribution and the shadowing effect between control rods during rod-worth measurements using the rod-drop experiment. A simulation-based instrumental calibration methodology is proposed to account for spatial effects on neutron detector responses and improve the accuracy of reactivity measurements. The IPEN/MB-01 research reactor was modeled using the MCNP Monte Carlo neutron transport code. Reactivity behavior during the initial transient of the rod-drop experiment (t < 10 s) was evaluated and compared…
arXiv:2611.17356v1 Announce Type: new Abstract: With the rapid development of high-sampling-rate digital nuclear devices, their applications in nuclear facilities and related fields become more acceptable, and will possibly become widespread due to the versatility and flexibility of waveform sampling systems. When digitizers reach hundreds of megahertz or gigahertz, their lower limit in time measurement probes into the sub-nanosecond region, expediting their use in a bunch of time-critical scenarios. While conventional algorithms coupled with digital sampling techniques realize fair pulse…
arXiv:2611.17351v1 Announce Type: new Abstract: Knowledge of the neutron flux distribution is essential for safe and effective reactor utilisation. In the SAFARI-1 research reactor, a set of axial flux profiles are periodically measured by activating natural copper wires inserted along the height of the fuel or control assemblies and subsequently measuring their activity using a sodium iodide detector. Improper wire insertion can, however, result in profiles that do not accurately represent the actual neutron flux distribution. Building on previously identified potential indicators of…
All items from this source